Jet Pressure Set
Stuart Turner Jet 80-45 PS 46618
- Established 1975
- Trusted by thousands of customers
Jet 80-45 PS – Centrifugal Pressure Set
Ideal for the high pressure delivery of clean non-potable water from a water tank/cistern in either a positive or negative head application.
Jet Pressure Sets include a 24 litre diaphragm tank providing a buffer of 12 litres of pressurised stored water and are supplied with a power lead fitted with a 13 amp fused plug.
The range is suitable for general purpose use, pumping cold water
More about this product
Technical Specification
| General | |
| Product code | 46618 |
| Guarantee | 1 year |
| Features | |
| Pump type | Centrifugal |
| Mechanical seal | EPDM / Carbon / Ceramic |
| Fully automatic control | |
| 24 litre diaphragm tank | |
| Built in 'no water' cut out | |
| Positive and negative head application | |
| Quiet operation | |
| Performance | |
| Maximum head (closed valve) | 4.5 bar |
| Performance @ 10 l/min | 3.6 bar |
| Performance @ 40 l/min | 2.5 bar |
| Maximum flow | 80 l/min |
| Minimum static inlet pressure | 0.1 bar (1 metre) |
| Maximum static inlet pressure | 0.5 bar (5 metres) |
| Maximum static outlet pressure | 1.3 bar (13 metres) |
| Maximum working pressure* | 500 kPa (5 bar) |
| Maximum ambient air temperature | 40 °C |
| Min / Max water temperature | Min 4 °C / Max 35 °C |
| Maximum suction lift | 5 metres |
| Cut out flow | 1 l/min (approx) |
| Cut in pressure | 180 kPa (1.8 bar) |
| Pressure vessel air pre-charge | 2.0 bar (29 psi) |
| Connections | |
| Pump connections | G 1 female |
| Motor | |
| Type | Induction, auto-reset thermal trip |
| Duty rating | Continuous (S1) |
| Electrical | |
| Power supply/phase/frequency | 230 V a.c./ 1 / 50 Hz |
| Current (full load) | 5.2 Amps |
| Power consumption | 925 Watts |
| Fuse rating | 13 Amps |
| Power cable (pre-wired) | 1.5 metres |
| Physical | |
| Enclosure protection | IPX4 |
| Length | 521 mm |
| Width | 280 mm |
| Height (excluding hoses) | 700 mm |
| Weight (including fittings) | 15.7 Kg |
* The maximum pressure that can be applied to the pump under any installation conditions.
-
data sheet PDFDownload
-
instructions PDFDownload
-
performance PDFDownload
-
dimensions PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.
Frequently Asked Questions
Quick answers to common questions about the Stuart Turner Jet 80-45 PS 46618. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.
What is a mains pressure boosting system?
A mains pressure boosting system increases the pressure and flow of water from the incoming mains supply into a property. It typically combines a pump and a storage or expansion tank, drawing water from the mains and delivering it to taps, showers and appliances at a stronger, more consistent pressure. They are used where the incoming mains is too weak to serve modern outlets reliably.
When do I need a mains booster pump?
You normally need a mains booster if static mains pressure is below 1.5 to 2 bar, if showers run weakly when other taps are open, or if combi boilers struggle to deliver hot water. Anglian Pumping recommends checking static pressure at the stop tap before specifying a system, then choosing a model rated for the number of bathrooms and outlets in the property.
What size mains booster do I need for my home?
Sizing depends on the number of bathrooms, the type of fittings and the static mains pressure. As a guide, a 1 to 2 bathroom property with combi boiler or single shower often needs 1.6 to 3 bar boost. A 2 to 3 bathroom property typically needs 3 to 4.5 bar with an integral break tank. Larger homes need a tank-and-pump system such as the DAB Esybox with Esytank or a Powertank set.
What is a water booster pump?
A water booster pump increases the pressure of an existing water supply to give stronger flow at taps, showers and appliances. It can be a small inline pump fitted to the incoming mains, or a larger pump and tank set that draws from a break tank to feed the whole house. Boosters do not create water – they raise the pressure of the water already coming in.
What is the difference between an inline booster and a tank-and-pump booster?
An inline booster connects straight onto the incoming mains and is limited to 12 litres per minute under UK water regulations – examples include the Salamander HomeBoost and WaterBoost WB-Compact. A tank-and-pump booster, such as the Grundfos Home Booster or DAB Esybox with Esytank, draws from a break tank and can deliver much higher flow rates for larger homes with multiple bathrooms.
What is a variable speed booster pump?
A variable speed booster uses an inverter to adjust pump speed in real time to match demand. It maintains constant pressure as outlets open and close, runs more quietly than a fixed-speed pump and typically saves up to 50 per cent of the energy a fixed-speed equivalent would use. The DAB Esybox, DAB Esybox Mini 3 and Grundfos Scala2 are common variable speed examples.