DAB Evoplus 40/180 SAN M electronic circulator, 230 V single-phase
Compact wet rotor electronic circulator with bronze pump body designed for the circulation of domestic hot water in commercial building service. It is equipped with an integrated variable frequency drive to ensure better all-round performance and energy efficiency, it also protects the system against water hammer action.
More about this product
Overview
Compact wet rotor electronic circulator with bronze pump body designed for the circulation of domestic hot water in commercial building service. It is equipped with an integrated variable frequency drive to ensure better all-round performance and energy efficiency, it also protects the system against water hammer action. The operating parameters, like proportional or constant differential pressure and constant speed, can be easily viewed and set on the user-friendly display. Synchronous motor with permanent magnet rotor. Flanged in-line suction and delivery ports. The circulator is WRAS-certified. Possibility of remote control with the DConnect service (DConnect Box supplied separately).
Specification
| Model | DAB Evoplus 40/180 SAN M |
|---|---|
| Part number | 60151144 |
| Supply | 220-240 V single-phase, 50/60 Hz |
| Max. power input P1 | 70 W |
| Current In | 0.52 A |
| Liquid temperature | From -10 °C to +110 °C |
| Max. operating pressure | 16 bar |
| Min. suction pressure at 90 °C | 20 m water column |
| Min. suction pressure at 100 °C | 25 m water column |
| Port-to-port length | 180 mm |
| Connections | 1“ F |
| Weight | 4.5 kg |
Evoplus San range
| Flow rate | From 67 to 700 l/min |
|---|---|
| Head | 17 metres |
| Liquid temperature | From -10°C to +110°C |
| Maximum operation pressure | 16 bar (1600 kPa). |
| Motor protection class | IP 44 |
| Insultion class | F |
TECHNICAL DATA
Circulator protection rate: IP 44.
Insulation class: F.
Standard voltage: single-phase 220/240V, 50/60Hz. In accordance with European standards: EN 61800-3 – EN 60335-1 – EN 60335-2-51.
Operating range: from 2 to 75.6 m3/h with head up to 18 meters.
Liquid Temperature range: from -10 °C to 110 °C.
Pumped liquid: clean, free from solids and mineral oils, not viscous, chemically neutral, close to the properties of water (max. glycol contents 30%).
Maximum working pressure: 16 bar (1600 kPa). Standard flanging: DN 32, DN 40, DN 50, DN 65, PN 6 / PN 10 / PN 16 (4 slots), DN 80 e DN 100, PN 6 (4 slots) usable with flange 4 holes PN10.
Special version on demand: DN 80 , DN 100 PN 10 / PN 16 (8 holes) Installation: with horizontal motor shaft
-
Data Sheet PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.
Frequently Asked Questions
Quick answers to common questions about the DAB EVOPLUS 40/180 SAN M – 60151144 (now 60231375). For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.
What is a water booster pump?
A water booster pump increases the pressure of an existing water supply to give stronger flow at taps, showers and appliances. It can be a small inline pump fitted to the incoming mains, or a larger pump and tank set that draws from a break tank to feed the whole house. Boosters do not create water – they raise the pressure of the water already coming in.
What is the difference between an inline booster and a tank-and-pump booster?
An inline booster connects straight onto the incoming mains and is limited to 12 litres per minute under UK water regulations – examples include the Salamander HomeBoost and WaterBoost WB-Compact. A tank-and-pump booster, such as the Grundfos Home Booster or DAB Esybox with Esytank, draws from a break tank and can deliver much higher flow rates for larger homes with multiple bathrooms.
What is a variable speed booster pump?
A variable speed booster uses an inverter to adjust pump speed in real time to match demand. It maintains constant pressure as outlets open and close, runs more quietly than a fixed-speed pump and typically saves up to 50 per cent of the energy a fixed-speed equivalent would use. The DAB Esybox, DAB Esybox Mini 3 and Grundfos Scala2 are common variable speed examples.
What does a water booster pump do?
A water booster pump raises water pressure to help supply taps, showers and other outlets when the existing system cannot meet demand.
Can a booster pump connect directly to the water mains?
Not every booster can. Direct connection depends on the product design and applicable water regulations; some systems require a break tank.
How do I size a water booster pump?
Assess simultaneous flow demand, required outlet pressure, available inlet conditions and the pressure losses in the pipework.