Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
Pedrollo VX 40/80 Three Phase 2302540
- Established 1975
- Trusted by thousands of customers
The Pedrollo VX 40/80 is a 3 kW (4 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to 1200 l/min and 11.5 m head.
Part of Pedrollo’s heavy-duty VX range, in thick stainless steel and cast iron, with a VORTEX impeller and flanged delivery.
More about this product
Product overview
The Pedrollo VX 40/80 is a 3 kW (4 HP) heavy-duty submersible vortex pump for sewage and waste water on a 400 V three-phase supply, covering 200 to 1200 l/min with a working head of 11.5 m down to 3 m. The VORTEX impeller is known for reliable operation and minimal risk of clogging.
The heavy-duty VX is built from thick stainless steel and cast iron for robustness, abrasion resistance and durability. It is recommended for sewage with suspended solids, waste water, rainwater, city sewage and industrial waste water, in sewers, tunnels, excavations, canals and underground car parks. The three-phase motor has a built-in thermal protector that trips on overheating or abnormal current draw.
Key features
Typical applications
Technical specifications
| Brand / Series | Pedrollo — VX |
| Model | VX 40/80 |
| Pedrollo code | 2302540 |
| Supply | 400 V three-phase |
| Motor power (P2) | 3 kW / 4 HP |
| Motor | 400 V three-phase motor with built-in thermal protection |
| Flow range | 200–1200 l/min |
| Head range | 11.5–3 m |
| Pump body | Cast iron (cataphoresis treated) |
| Impeller | VORTEX, cast iron (cataphoresis treated) |
| Motor sleeve | AISI 304 stainless steel |
| Motor cover | Cast iron (cataphoresis treated) |
| Motor shaft | AISI 431 stainless steel |
| Mechanical seals | Double mechanical seal with interposed oil chamber: silicon carbide / graphite / NBR (motor side), silicon carbide / silicon carbide / NBR (pump side) |
| Port | DN80 (3″) flanged, PN10 |
| Solids passage | Up to Ø 80 mm |
| Float switch | None (manual) |
| Power cable | 10 m (H07 RN-F) |
| Minimum immersion (continuous) | 500 mm |
| Maximum depth | 10 m below water level |
| Liquid temperature | Up to +40 °C |
| Insulation / protection | Class F / IP X8 |
| Liquid | Sewage, waste water and rainwater with suspended solids |
VX DN50–DN80 range
| Model | Code | Supply | Power | Flow | Head |
|---|---|---|---|---|---|
| VX 40/50 | 2302490 | Three Phase | 3 kW / 4 HP | 100–900 l/min | 22–5.5 m |
| VX 55/50 | 2302500 | Three Phase | 4 kW / 5.5 HP | 100–1000 l/min | 25–6.5 m |
| VX 40/65 | 2302510 | Three Phase | 3 kW / 4 HP | 200–1200 l/min | 15.6–2.5 m |
| VX 55/65 | 2302520 | Three Phase | 4 kW / 5.5 HP | 200–1350 l/min | 19.4–3.7 m |
| VX 75/65 | 2302530 | Three Phase | 5.5 kW / 7.5 HP | 200–1500 l/min | 23.6–5.5 m |
| VX 40/80 | 2302540 | Three Phase | 3 kW / 4 HP | 200–1200 l/min | 11.5–3 m |
| VX 55/80 | 2302550 | Three Phase | 4 kW / 5.5 HP | 200–1400 l/min | 16–4 m |
| VX 75/80 | 2302560 | Three Phase | 5.5 kW / 7.5 HP | 200–1800 l/min | 21–4.5 m |
| VX4 10/50 | 2305510 | Three Phase | 0.75 kW / 1 HP | 100–600 l/min | 6.4–1 m |
| VX4 10/65 | 2305520 | Three Phase | 0.75 kW / 1 HP | 100–900 l/min | 6–1 m |
| VX4 10/80 | 2305530 | Three Phase | 0.75 kW / 1 HP | 100–900 l/min | 5.3–1 m |
Head shown as the working range from minimum to maximum flow. Performance to Pedrollo 50 Hz data.
Frequently asked questions
What size solids will it pass?
Up to Ø 50 mm on the /50 models, Ø 65 mm on the /65 and Ø 80 mm on the /80.
Is there a single-phase version?
No. The DN50 to DN80 VX models are three-phase 400 V only.
Can it go on a guide rail?
Yes. Pedrollo guide rail kits are available: horizontal delivery 2302640 (VX /50), vertical delivery 2302660 (VX /50), 2302670 (VX /65) and 2302680 (VX /80).
-
Data Sheet PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.
Frequently Asked Questions
Quick answers to common questions about the Pedrollo VX 40/80 Three Phase 2302540. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.
What is a submersible pump?
A submersible pump is designed to operate fully submerged in the liquid it is moving. The motor is sealed inside the pump body and cooled by the surrounding water. Submersibles are used for drainage, sewage, septic tanks, deep wells and boreholes, and for raising water from sumps, cellars and floodwater. Many stocked at Anglian Pumping handle solids in suspension.
Can submersible pumps handle solids and sewage?
Yes – some submersibles are designed for clean water only, others handle solids up to 50 mm or full raw sewage. Anglian Pumping stocks ABS, BBC, Flygt and T-T Submersibles ranges that include vortex, single channel and grinder impellers for different solids handling requirements. Always match the pump to the maximum solid size and the type of effluent it will see.
When should I use a submersible pump instead of a surface pump?
Use a submersible when the water level is more than around 8 metres below the pump installation point – surface pumps cannot self-prime beyond that depth. Submersibles are also better when the liquid contains solids, when noise must be minimised, or when the pump needs to operate in confined spaces such as sumps and chambers where a surface pump would not fit.