Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80

The Pedrollo VX DN50 to DN80 range is a heavy-duty three-phase submersible vortex pump in thick stainless steel and cast iron, for sewage with suspended solids, waste water, rainwater, city sewage and industrial waste water. Eight 2-pole models deliver up to 1,800 l/min and up to 25 m head from 3 to 5.5 kW, plus three 4-pole VX4 models (0.75 kW, 1,450 rpm) for lower heads.

Cast iron pump body and VORTEX impeller with cataphoresis treatment, AISI 304 motor sleeve, AISI 431 shaft and a double mechanical seal with an oil chamber. Flanged DN50, DN65 or DN80 delivery (PN10), passing solids up to Ø 50, 65 or 80 mm. 400 V three-phase motor with built-in thermal protection, 10 m cable, depth to 10 m.

1800l/min
Max flow
25m
Max head
0.75–5.5kW
Motor range
11
Models
ModelCodeSupplyPowerFlowHead
VX 40/502302490Three Phase3 kW / 4 HP100–900 l/min22–5.5 m
VX 55/502302500Three Phase4 kW / 5.5 HP100–1000 l/min25–6.5 m
VX 40/652302510Three Phase3 kW / 4 HP200–1200 l/min15.6–2.5 m
VX 55/652302520Three Phase4 kW / 5.5 HP200–1350 l/min19.4–3.7 m
VX 75/652302530Three Phase5.5 kW / 7.5 HP200–1500 l/min23.6–5.5 m
VX 40/802302540Three Phase3 kW / 4 HP200–1200 l/min11.5–3 m
VX 55/802302550Three Phase4 kW / 5.5 HP200–1400 l/min16–4 m
VX 75/802302560Three Phase5.5 kW / 7.5 HP200–1800 l/min21–4.5 m
VX4 10/502305510Three Phase0.75 kW / 1 HP100–600 l/min6.4–1 m
VX4 10/652305520Three Phase0.75 kW / 1 HP100–900 l/min6–1 m
VX4 10/802305530Three Phase0.75 kW / 1 HP100–900 l/min5.3–1 m

Head shown as the working range from minimum to maximum flow. Performance to Pedrollo 50 Hz data.

Heavy dutySolids up to 80 mmFlanged DN50–DN80Three-phase
Logo for Pedrollo

11 products

    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 40/50 Three Phase 2302490

    The Pedrollo VX 40/50 is a 3 kW (4 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 55/50 Three Phase 2302500

    The Pedrollo VX 55/50 is a 4 kW (5.5 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 40/65 Three Phase 2302510

    The Pedrollo VX 40/65 is a 3 kW (4 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 55/65 Three Phase 2302520

    The Pedrollo VX 55/65 is a 4 kW (5.5 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 75/65 Three Phase 2302530

    The Pedrollo VX 75/65 is a 5.5 kW (7.5 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 40/80 Three Phase 2302540

    The Pedrollo VX 40/80 is a 3 kW (4 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 55/80 Three Phase 2302550

    The Pedrollo VX 55/80 is a 4 kW (5.5 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX 75/80 Three Phase 2302560

    The Pedrollo VX 75/80 is a 5.5 kW (7.5 HP) heavy-duty submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX4 10/50 Three Phase 2305510

    The Pedrollo VX4 10/50 is a 0.75 kW (1 HP) 4-pole submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX4 10/65 Three Phase 2305520

    The Pedrollo VX4 10/65 is a 0.75 kW (1 HP) 4-pole submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product
    Logo for Pedrollo
    Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80
    Pedrollo VX4 10/80 Three Phase 2305530

    The Pedrollo VX4 10/80 is a 0.75 kW (1 HP) 4-pole submersible vortex pump for sewage on a 400 V three-phase supply, delivering up to…

    View Product

Frequently Asked Questions

Quick answers to common questions about the Pedrollo VX Flanged Vortex Sewage Pumps DN50 to DN80. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.

What is a submersible pump?

A submersible pump is designed to operate fully submerged in the liquid it is moving. The motor is sealed inside the pump body and cooled by the surrounding water. Submersibles are used for drainage, sewage, septic tanks, deep wells and boreholes, and for raising water from sumps, cellars and floodwater. Many stocked at Anglian Pumping handle solids in suspension.

Can submersible pumps handle solids and sewage?

Yes – some submersibles are designed for clean water only, others handle solids up to 50 mm or full raw sewage. Anglian Pumping stocks ABS, BBC, Flygt and T-T Submersibles ranges that include vortex, single channel and grinder impellers for different solids handling requirements. Always match the pump to the maximum solid size and the type of effluent it will see.

When should I use a submersible pump instead of a surface pump?

Use a submersible when the water level is more than around 8 metres below the pump installation point – surface pumps cannot self-prime beyond that depth. Submersibles are also better when the liquid contains solids, when noise must be minimised, or when the pump needs to operate in confined spaces such as sumps and chambers where a surface pump would not fit.