Pedrollo MC4 4-Pole Double-Channel Sewage Pumps
Pedrollo MC4 200/80 Three Phase 2302820
- Established 1975
- Trusted by thousands of customers
The Pedrollo MC4 200/80 is a 15 kW (20 HP) 4-pole submersible double-channel pump for sewage on a 400 V three-phase supply, delivering up to 5000 l/min and 26 m head.
Part of Pedrollo’s heavy-duty MC4 range: a 1,450 rpm, three-phase double-channel pump in thick cast iron with DN100 flanged delivery.
More about this product
Product overview
The Pedrollo MC4 200/80 is a 15 kW (20 HP) 4-pole submersible double-channel pump for sewage on a 400 V three-phase supply, covering 800 to 5000 l/min with a working head of 26 m down to 12.5 m. The slower 1,450 rpm motor and two-channel impeller give robust, long-lasting service.
The MC4 is built from thick cast iron for exceptional robustness, abrasion resistance and durability. It drains liquids containing suspended solids and short fibres, sewage, sludge-mixed water, groundwater and surface water, in apartment buildings, public facilities, industry, car parks and washing areas. The motor has built-in three-phase thermal protection, which must be connected to the control panel for the warranty to apply.
Key features
Typical applications
Technical specifications
| Brand / Series | Pedrollo — MC4 |
| Model | MC4 200/80 |
| Pedrollo code | 2302820 |
| Supply | 400 V three-phase |
| Motor power (P2) | 15 kW / 20 HP |
| Motor | Three-phase 230/400 V or 400/690 V motor; built-in thermal protector must be connected to the control panel |
| Flow range | 800–5000 l/min |
| Head range | 26–12.5 m |
| Pump body | Cast iron (cataphoresis treated) |
| Impeller | Two-channel, cast iron (cataphoresis treated) |
| Motor holder and cover | Cast iron |
| Motor shaft | AISI 431 stainless steel |
| Mechanical seals | Double mechanical seal with oil chamber: ceramic / graphite / NBR (motor side), silicon carbide / silicon carbide / NBR (pump side) |
| Speed | 4-pole, 1,450 rpm |
| Port | DN100 (4″) flanged, PN10 |
| Solids passage | Up to Ø 80 mm |
| Power cable | 10 m (EM2) |
| Maximum depth | 10 m below water level |
| Liquid temperature | Up to +40 °C |
| Insulation / protection | Class F / IP X8 |
| Liquid | Sewage, sludge-mixed water, groundwater and surface water |
MC4 range
| Model | Code | Supply | Power | Flow | Head |
|---|---|---|---|---|---|
| MC4 40/55 | 2302760 | Three Phase | 3 kW / 4 HP | 400–2400 l/min | 10–3.6 m |
| MC4 50/55 | 2302770 | Three Phase | 3.7 kW / 5 HP | 400–2700 l/min | 12.6–4.8 m |
| MC4 55/55 | 2302780 | Three Phase | 4 kW / 5.5 HP | 400–2900 l/min | 14–5.3 m |
| MC4 100/80 | 2302790 | Three Phase | 7.5 kW / 10 HP | 800–4250 l/min | 17–7 m |
| MC4 125/80 | 2302800 | Three Phase | 9.2 kW / 12.5 HP | 800–4500 l/min | 19–8 m |
| MC4 150/80 | 2302810 | Three Phase | 11 kW / 15 HP | 800–4750 l/min | 21–9.5 m |
| MC4 200/80 | 2302820 | Three Phase | 15 kW / 20 HP | 800–5000 l/min | 26–12.5 m |
Head shown as the working range from minimum to maximum flow. Performance to Pedrollo 50 Hz data.
Frequently asked questions
What size solids will it pass?
Up to Ø 55 mm on the MC4 40/55, 50/55 and 55/55, and up to Ø 80 mm on the MC4 100/80 to 200/80.
Is there a single-phase version?
No. The MC4 is three-phase only.
Can it go on a guide rail?
Yes. Pedrollo’s MC4 guide-rail kits (vertical delivery, 2″ guide tubes) are available separately.
-
Data Sheet PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.
Frequently Asked Questions
Quick answers to common questions about the Pedrollo MC4 200/80 Three Phase 2302820. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.
What is a submersible pump?
A submersible pump is designed to operate fully submerged in the liquid it is moving. The motor is sealed inside the pump body and cooled by the surrounding water. Submersibles are used for drainage, sewage, septic tanks, deep wells and boreholes, and for raising water from sumps, cellars and floodwater. Many stocked at Anglian Pumping handle solids in suspension.
Can submersible pumps handle solids and sewage?
Yes – some submersibles are designed for clean water only, others handle solids up to 50 mm or full raw sewage. Anglian Pumping stocks ABS, BBC, Flygt and T-T Submersibles ranges that include vortex, single channel and grinder impellers for different solids handling requirements. Always match the pump to the maximum solid size and the type of effluent it will see.
When should I use a submersible pump instead of a surface pump?
Use a submersible when the water level is more than around 8 metres below the pump installation point – surface pumps cannot self-prime beyond that depth. Submersibles are also better when the liquid contains solids, when noise must be minimised, or when the pump needs to operate in confined spaces such as sumps and chambers where a surface pump would not fit.