Pedrollo 4SR-HYD 4-Inch Borehole Pump Ends
Pedrollo 4SR 1.5/22-S HYD 4-Inch Borehole Pump End 2202030
- Established 1975
- Trusted by thousands of customers
The Pedrollo 4SR 1.5/22-S HYD is a 4″ submersible borehole pump end for a 1.1 kW (1.5 HP) motor, delivering up to 45 l/min and 154 m head.
Pump end only, with no motor. Fit it to a 4″ motor of 1.1 kW (1.5 HP); its AISI 304 stainless steel motor bracket follows NEMA standards. Pedrollo’s 4SR-S hydraulics resist sand wear and handle water with up to 200 g/m³ of sand.
More about this product
Product overview
The Pedrollo 4SR 1.5/22-S HYD is a 4″ submersible borehole pump end for clean water, covering 5 to 45 l/min with a working head of 154 m down to 52.5 m. It needs a 4″ motor of 1.1 kW (1.5 HP). Pedrollo’s own 4″ motors are the 4PD rewindable oil-filled and 4PS encapsulated water-filled types.
The 4SR-S series uses floating impellers and patented hydraulics that resist sand wear, handling water with up to 200 g/m³ of sand. A patented inductor improves priming in wells where the water carries air or gas. It suits domestic, civil and industrial use, including water distribution with autoclave tanks, irrigation, washing systems and pressure boosting.
Its delivery port is micro-cast AISI 304 stainless steel with an ISO 228/1 thread. The check valve, motor bracket (sized to NEMA standards), stage box, pump shaft, filter and cable sheath are AISI 304 stainless steel, and the pump bearings are AISI 316L stainless steel coated with chromium oxide to resist sand.
Key features
Typical applications
Technical specifications
| Brand / Series | Pedrollo — 4SR-S HYD |
| Model | 4SR 1.5/22-S HYD (pump end) |
| Pedrollo code | 2202030 |
| Supplied as | Pump end only, no motor |
| Motor needed | 4″ motor, 1.1 kW / 1.5 HP (P2) |
| Flow range | 5–45 l/min |
| Head range | 154–52.5 m |
| Delivery port | 1¼″ ISO 228/1, micro-cast AISI 304 stainless steel |
| Check valve | AISI 304 stainless steel |
| Impellers | Delrin® |
| Diffusers | Noryl™ |
| Stage box | AISI 304 stainless steel |
| Pump shaft | AISI 304 stainless steel |
| Pump bearings | AISI 316L stainless steel, chromium oxide coated |
| Coupling | Stainless steel |
| Motor bracket | AISI 304 stainless steel, sized to NEMA standards |
| Filter and cable sheath | AISI 304 stainless steel |
| Pump end length | 627 mm |
| Minimum well diameter | 4″ (100 mm) |
| Maximum sand content | 200 g/m³ |
| Liquid temperature | Up to +40 °C |
| Installation | Vertical or horizontal |
| Maximum depth | 200 m below water level with 4PD motors, 300 m with 4PS motors |
| Minimum motor cooling flow | 8 cm/s |
| Starts per hour | 20, at regular intervals |
| Efficiency index | MEI ≥ 0.40 |
| Liquid | Clean water |
Installation
4SR 1.5-S range
| Model | Code | Motor needed | Flow | Head | Delivery |
|---|---|---|---|---|---|
| 4SR 1.5/7-S | 2202000 | 0.37 kW / 0.5 HP | 5–45 l/min | 50–17 m | 1¼″ |
| 4SR 1.5/11-S | 2202010 | 0.55 kW / 0.75 HP | 5–45 l/min | 78–26.5 m | 1¼″ |
| 4SR 1.5/15-S | 2202020 | 0.75 kW / 1 HP | 5–45 l/min | 106–36 m | 1¼″ |
| 4SR 1.5/22-S | 2202030 | 1.1 kW / 1.5 HP | 5–45 l/min | 154–52.5 m | 1¼″ |
| 4SR 1.5/30-S | 2202040 | 1.5 kW / 2 HP | 5–45 l/min | 206–70 m | 1¼″ |
| 4SR 1.5/44-S | 2202050 | 2.2 kW / 3 HP | 5–45 l/min | 295–100 m | 1¼″ |
Head shown as the working range from minimum to maximum flow. Performance to Pedrollo 50 Hz data. Pump ends only, without motors.
Frequently asked questions
Does it come with a motor?
No. This is the pump end only. Fit it to a 4″ motor of 1.1 kW (1.5 HP); the AISI 304 motor bracket follows NEMA standards.
What size borehole does it need?
Wells with a minimum diameter of 4″ (100 mm).
How much sand can it handle?
Up to 200 g/m³. The AISI 316L pump bearings carry a chromium oxide coating to resist sand.
Can I install it horizontally?
Yes. Pedrollo allow horizontal installation on the 4SR 1.5 up to 23 stages, and this model has 22.
How deep can it go?
Up to 200 m below water level with a Pedrollo 4PD motor, or 300 m with a 4PS motor.
-
Data Sheet PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.
Frequently Asked Questions
Quick answers to common questions about the Pedrollo 4SR 1.5/22-S HYD 4-Inch Borehole Pump End 2202030. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.
What is a submersible pump?
A submersible pump is designed to operate fully submerged in the liquid it is moving. The motor is sealed inside the pump body and cooled by the surrounding water. Submersibles are used for drainage, sewage, septic tanks, deep wells and boreholes, and for raising water from sumps, cellars and floodwater. Many stocked at Anglian Pumping handle solids in suspension.
Can submersible pumps handle solids and sewage?
Yes – some submersibles are designed for clean water only, others handle solids up to 50 mm or full raw sewage. Anglian Pumping stocks ABS, BBC, Flygt and T-T Submersibles ranges that include vortex, single channel and grinder impellers for different solids handling requirements. Always match the pump to the maximum solid size and the type of effluent it will see.
When should I use a submersible pump instead of a surface pump?
Use a submersible when the water level is more than around 8 metres below the pump installation point – surface pumps cannot self-prime beyond that depth. Submersibles are also better when the liquid contains solids, when noise must be minimised, or when the pump needs to operate in confined spaces such as sumps and chambers where a surface pump would not fit.