PQ range
Pedrollo PQ 65 Three Phase 2100390
- Established 1975
- Trusted by thousands of customers
The Pedrollo PQ 65 is a 0.55 kW (0.75 HP) peripheral pump on a 400 V three-phase supply, delivering up to 50 l/min and 50 m head. Peripheral impeller pumps give high pressure from a small, simple pump.
Part of Pedrollo’s PQ range, for small pressure sets, transfer and washing where pressure matters more than flow.
More about this product
Product overview
The Pedrollo PQ 65 is a 0.55 kW (0.75 HP) peripheral pump on a 400 V three-phase supply, covering 5 to 50 l/min with a working head of 50 m down to 8 m. The peripheral (turbine) impeller builds pressure in a single stage, so the pump is compact and simple.
PQ pumps suit small domestic pressure sets, boiler feed, transfer and washing duties with clean water, and the Bs (brass body) and PPS versions extend the range to liquids that would attack cast iron. Install indoors or under cover.
Key features
Typical applications
Technical specifications
| Brand / Series | Pedrollo — PQ |
| Model | PQ 65 |
| Pedrollo code | 2100390 |
| Supply | 400 V three-phase |
| Motor power (P2) | 0.55 kW / 0.75 HP |
| Motor | Three-phase motor (IE2 or IE3 class to IEC 60034-30-1, by size) |
| Flow range | 5–50 l/min |
| Head range | 50–8 m |
| Pump body | Cast iron |
| Impeller | Brass |
| Liquid | Clean water, not chemically aggressive to the pump materials |
| Duty | Continuous S1 |
PQ range
| Model | Code | Supply | Power | Flow | Head |
|---|---|---|---|---|---|
| PQm 60 | 2100290 | Single Phase | 0.3 kW / 0.4 HP | 5–40 l/min | 38–5 m |
| PQ 60 | 2100380 | Three Phase | 0.3 kW / 0.4 HP | 5–40 l/min | 38–5 m |
| PQm 61 | 2100295 | Single Phase | 0.3 kW / 0.4 HP | 5–40 l/min | 38–5 m |
| PQ 61 | 2100385 | Three Phase | 0.3 kW / 0.4 HP | 5–40 l/min | 38–5 m |
| PQm 65 | 2100300 | Single Phase | 0.55 kW / 0.75 HP | 5–50 l/min | 50–8 m |
| PQ 65 | 2100390 | Three Phase | 0.55 kW / 0.75 HP | 5–50 l/min | 50–8 m |
| PQm 80 | 2100320 | Single Phase | 0.75 kW / 1 HP | 5–50 l/min | 66–22 m |
| PQ 80 | 2100410 | Three Phase | 0.75 kW / 1 HP | 5–50 l/min | 66–22 m |
| PQm 90 | 2100330 | Single Phase | 0.75 kW / 1 HP | 5–40 l/min | 82–5 m |
| PQ 90 | 2100420 | Three Phase | 0.75 kW / 1 HP | 5–40 l/min | 82–5 m |
| PQm 100 | 2100340 | Single Phase | 1.1 kW / 1.5 HP | 5–70 l/min | 80–15 m |
| PQ 100 | 2100430 | Three Phase | 1.1 kW / 1.5 HP | 5–70 l/min | 80–15 m |
| PQm 200 | 2100350 | Single Phase | 1.5 kW / 2 HP | 5–80 l/min | 86–10 m |
| PQ 200 | 2100440 | Three Phase | 1.5 kW / 2 HP | 5–80 l/min | 86–10 m |
| PQm 300 | 2100360 | Single Phase | 2.2 kW / 3 HP | 5–90 l/min | 95–10 m |
| PQ 300 | 2100450 | Three Phase | 2.2 kW / 3 HP | 5–90 l/min | 95–10 m |
| PQ 3000 MF | 2100470 | Three Phase | 2.2 kW / 3 HP | 5–50 l/min | 180–50 m |
| PQm 81 – PPS | 2112460 | Single Phase | 0.55 kW / 0.75 HP | 2–22 l/min | 83.5–10 m |
| PQ 81 – PPS | 2112470 | Three Phase | 0.55 kW / 0.75 HP | 2–22 l/min | 83.5–10 m |
| PQm 60-Bs | 2100480 | Single Phase | 0.3 kW / 0.4 HP | 2–40 l/min | 43–5 m |
| PQ 60-Bs | 2100510 | Three Phase | 0.3 kW / 0.4 HP | 2–40 l/min | 43–5 m |
| PQm 65-Bs | 2100490 | Single Phase | 0.55 kW / 0.75 HP | 1–46 l/min | 62–8 m |
| PQ 65-Bs | 2100520 | Three Phase | 0.55 kW / 0.75 HP | 1–46 l/min | 62–8 m |
| PQm 81-Bs | 2100500 | Single Phase | 0.55 kW / 0.75 HP | 1–24 l/min | 92–5 m |
| PQ 81-Bs | 2100530 | Three Phase | 0.55 kW / 0.75 HP | 1–24 l/min | 92–5 m |
| PQm 80-Bs | 2110970 | Single Phase | 0.75 kW / 1 HP | 2–50 l/min | 69–5 m |
| PQ 80-Bs | 2110980 | Three Phase | 0.75 kW / 1 HP | 2–50 l/min | 69–5 m |
Head shown as the working range from minimum to maximum flow. Performance to Pedrollo 50 Hz data.
Frequently asked questions
Is it self-priming?
No. It needs a flooded suction or a foot valve. The PKS range is the self-priming peripheral pump.
What is the Bs version?
The same pump with a brass body instead of cast iron, for softened water and liquids that would corrode cast iron.
What is the PPS version?
A pump body in PPS technopolymer with threaded brass inserts instead of cast iron, with the same brass impeller.
What water can it handle?
Clean water without abrasive particles; peripheral impellers have tight clearances and do not tolerate grit.
-
Data Sheet PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.