Wilo Stratos GIGA B Without Sensor
Wilo Stratos GIGA B 32/1-13/0,8-R1 DN 50 DN 32 2189134
- Established 1975
- Trusted by thousands of customers
Wilo Stratos GIGA B 32/1-13/0,8-R1 monobloc pump, 400 V three-phase
High-efficiency glanded pump in close-coupled design with EC motor of energy efficiency class IE5 in accordance with IEC 60034-30-2 and electronic power adjustment.
0.75 kW motor. Connections DN 50 suction, DN 32 discharge.
More about this product
Overview
High-efficiency glanded pump in close-coupled design with EC motor of energy efficiency class IE5 in accordance with IEC 60034-30-2 and electronic power adjustment. The pump is configured as a single-stage low-pressure centrifugal pump with flange connection and mechanical seal. The Stratos GIGA2.0-B is primarily designed for pumping heating water (acc. to VDI 2035), chilled water and water-glycol mixtures without abrasive substances in heating, air conditioning and cooling systems.
Specification
| Model | Wilo Stratos GIGA B 32/1-13/0,8-R1 |
|---|---|
| Part number | 2189134 |
| Series | Stratos GIGA B |
| Supply | 400 V three-phase, 50/60 Hz |
| Rated power P2 | 0.75 kW |
| Max. power consumption P1 | 0.90 kW |
| Max. current | 1.5 A |
| Max. operating pressure | 16 bar |
| Fluid temperature | -20 °C to 140 °C |
| Ambient temperature | -30 °C to 50 °C |
| Dimensioning note | 16 bar to 120 °C, 13 bar to 140 °C |
| Minimum efficiency index (MEI) | ≥ 0.7 |
| Motor efficiency class | IE5 |
| Protection class | IP55 |
| Insulation class | F |
| Motor protection | PTC integrated |
Materials
| Pump housing | 5.1301/EN-GJL-250 KTL-coated |
|---|---|
| Impeller | PPS-GF40 |
| Shaft | Stainless steel |
| Shaft seal | AQ1EGG |
| Lantern | 5.1301/EN-GJL-250 KTL-coated |
Approved liquids
| Heating water (as per VDI 2035) | Yes |
|---|---|
| Heat carrier oil | Special version at additional charge |
| Water-glycol mixtures (at 20 – 40 vol. % glycol and fluid temperature ≤ 40 °C) | Yes |
Other liquids on request.
Dimensions and weight
| Pipe connection, suction | DN 50 |
|---|---|
| Pipe connection, discharge | DN 32 |
| Length × width × height | 585 × 307 × 352 mm |
| Net weight | 37 kg |
Features and equipment
…-R1 design
- Single-stage low-pressure centrifugal pump in close-coupled design with a one-piece shaft or split shaft (depending on the pump type), including a foot on the pump housing
- Flange and housing dimensions according to EN 733
- PN 16 flange – drilled according to EN 1092-2
- Pressure measuring connections (R 1/8) for mounted differential pressure sensor (…-R1 version without differential pressure sensor)
- Pump housing and motor flange with cataphoretic coating as standard
- Mechanical seal for pumping water up to Tmax. = +140 °C. A glycol admixture of 20% to 40% by volume is permissible up to T ≤ +40 °C. An alternative mechanical seal must be provided for water-glycol mixtures with a glycol content of > 40% to max. 50% by volume and a fluid temperature of > +40 °C to max. +120 °C or other fluids that differ from water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.
- Connection voltages
- 3~440 V ±10% 50/60 Hz; 3~400 V ±10% 50/60 Hz; 3~380 V -5% +10% 50/60 Hz
- Compliance with electromagnetic compatibility without additional measures
- Interference emission for residential environment according to EN 61800-3:2018
- Interference immunity for industrial environments according to EN 61800-3:2018
Control modes
- Constant speed (n-const.)
- Constant temperature (T-const.)
- Constant differential temperature (dT-const.)
- User-defined PID control
- Only possible with differential pressure sensor
- Permanent, automatic power adjustment to system requirements without setpoint specification Wilo Dynamic Adapt plus (factory setting).
- Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple secondary pumps (Multi-Flow Adaptation).
- Constant volume flow (Q-const.)
- Variable differential pressure (dp-v) with the option to set the nominal duty point Q and H
- Constant differential pressure (dp-c)
- Differential pressure control (dp-c) at a remote point in the pipe network (index circuit evaluator)
Functions
- Selection of the field of application in the setting assistant
- Operating modes of twin-head pump/two-pump system: Main/standby mode
- Switchover between heating and cooling mode (automatic, external or manual)
- Ability to save and restore configured pump settings (3 restoration points)
- Fault and warning messages displayed in plain text with advice on resolving the issue
- Integrated full motor protection
- Only possible with differential pressure sensor
- Heat quantity measurement
- Cooling quantity measurement
- Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.)
- Pump switches off automatically when zero flow is detected (No-Flow Stop)
- Efficiency-optimised parallel operation for dp-c and dp-v
Display in the “Home screen” of the graphic display
- Control mode currently set
- Current setpoint
- Current volume flow (only if a differential pressure sensor is connected)
- Current fluid temperature (only if temperature sensor is connected)
- Current power consumption
- Cumulative electric consumption
Version
- 4 configurable analogue inputs: 0-10 V, 2-10 V, 0-20 mA, 4-20 mA and commercially available PT1000 (only on two analogue inputs); +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurabl
Frequently asked questions
-
Data Sheet PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.
Frequently Asked Questions
Quick answers to common questions about the Wilo Stratos GIGA B 32/1-13/0,8-R1 DN 50 DN 32 2189134. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.
What types of Wilo pumps are available?
Wilo manufactures circulators and other pumping solutions for heating, cooling, water supply and building services applications.
What is a Wilo circulator pump used for?
A Wilo circulator moves water around a heating or cooling circuit to maintain the required flow through the system.
How do I select a replacement Wilo pump?
Match the existing model or confirm head, flow, installation length, connections, voltage and control requirements before ordering.