Triton LR02
Triton LR02 Rubber Float Switch with Inbuilt Weight 20m LR02-L20M
- Established 1975
- Trusted by thousands of customers
The Triton LR02-L20M is Triton Controls’ best-selling float switch for sewage and wastewater. A tough Hypalon rubber float houses a sealed microswitch and steel roller ball, moulded to 20 m of 3-core CPE cable, with a built-in stabilising weight, so no separate counterweight is needed.
Its changeover (SPDT) contact switches a pump directly up to 15 A resistive at 250 V, and can be wired to fill or empty. Made in the UK by Triton Controls.
More about this product
Triton LR02 rubber float switch, 20 m
The Triton LR02 (LR02-L20M) has been Triton Controls’ best-selling float switch for over 20 years, and is the standard choice for sewage and wastewater level control. A sealed microswitch and steel roller ball sit inside a tough Hypalon (CSP) synthetic rubber float, moulded to 20 m of 3-core CPE cable. A rubber-coated stabilising weight is fixed to the cable about 120 mm from the float, so no separate counterweight is needed.
Its smooth, rounded shape resists build-up of solids and grease. As the level rises or falls, the changeover (SPDT) contact starts or stops a pump, or triggers an alarm. Wire one side to empty a sump or wet well, or the other side to fill a tank.
Specifications
| Part number | LR02-L20M |
| Cable length | 20 m (±5%) |
| Switch type | SPDT changeover microswitch, steel roller ball operated (non-mercury) |
| Contact rating | 250 V 15 A non-inductive; 250 V 10 A inductive (1.3 hp) |
| Float | Hypalon (CSP) synthetic rubber over sealed closed-cell foam |
| Cable | 3-core CPE synthetic rubber: brown, blue, black |
| Stabilising weight | Built in, rubber coated, about 120 mm from the float |
| Float size | 174 × 91 mm |
| Max liquid temperature | 70°C |
| Max submerged depth | 20 m |
| Compressive strength | 482 kN/m² (70 lbf/in²) |
| Specific gravity range | 0.8 to 1.3 |
| Manufacturer | Triton Controls, made in Great Britain |
Wiring
| Leads used | Contact closes when | Typical use |
|---|---|---|
| Brown + Black | Float rises (tilts up past about 45°) | Emptying: pump starts on high level |
| Brown + Blue | Float falls (tilts down past about 45°) | Filling: pump or valve starts on low level; low-level / dry-run alarm |
Brown is the common lead. Insulate whichever lead you don’t use. Single-phase pumps up to 10 A inductive can be switched directly. Larger or three-phase motors should be switched through a contactor or control panel.
Chemical resistance
| Against | Rating |
|---|---|
| Water, salt water | Good |
| Vegetable & animal fats | Good |
| Dilute acids, alkalis, alcohols | Good |
| Sunlight, ozone, oxidation | Good |
| Lubricants | Fair |
| Diesel oil & petrol | Poor |
Applications
Cable length options
| Part number | Cable length |
|---|---|
| LR02-L05M | 5 m |
| LR02-L10M | 10 m |
| LR02-L15M | 15 m |
| LR02-L20M (this listing) | 20 m |
| LR02-L30M | 30 m |
| LR02-L40M | 40 m |
Installation tips
- Allow at least 330 mm of free movement so the float can tilt fully. Switching points are approximate.
- In an enclosed vessel, support the cable; in an open or turbulent tank, clip it to the wall so the float cannot drift.
- Where turbulence causes rapid on/off switching, use a maintaining (latching) circuit to protect the microswitch and the pump starter.
FAQs
Does the LR02 need a counterweight?
No. The stabilising weight is built into the cable about 120 mm from the float, so it is ready to hang straight into the sump.
Can one switch fill and empty a tank?
Yes. Use brown and black to empty (closes on rising level) or brown and blue to fill (closes on falling level).
Will it switch my pump directly?
Single-phase pumps up to 10 A inductive (about 1.3 hp) at 250 V, yes. Use a contactor or control panel for larger or three-phase pumps.
Can I use it in diesel or oil?
No. The LR02 is rated poor against diesel and petrol. Use the Triton LR06, which has a polyurethane cable made for oily liquids.
Is there a version for hazardous areas?
Yes. The Triton LR02-IS is ATEX certified for zones 1 and 2, wired through an intrinsically safe barrier.
-
data sheet PDFDownload
Standard delivery:
Standard delivery is free on most orders. Some items may incur a delivery charge depending on weight, size or value. Any applicable charge will be displayed at checkout.
Deliveries will typically be made between 7am and 6pm, Monday to Friday (excluding public holidays).
Next day delivery:
Next working day delivery is available for a £16.50 + VAT delivery charge.
Orders must be placed before 12 noon to qualify for next working day delivery. Orders placed after 12 noon on Thursday but before noon on Friday will be delivered the following Monday. Orders placed after 12 noon on Friday will be delivered on Tuesday.
Pallet/Large/Difficult items:
Some large, heavy or difficult to transport items may incur an additional delivery charge. Please contact us for a delivery quote before ordering.