LOGIN / REGISTER
Trade
Secure Payments
Free delivery on a wide range of products

DAB Single Electronic Pumps - 4 pole - CME / CM-GE - Flanged

DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged

42 models in the DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged.

DAB
Logo for DAB

Showing 31–41 of 41 products

    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 125-2550/A/BAQE/15 T MCE150/CIE3 - 60167289

    DAB CM-GE 125-2550/A/BAQE/15 T MCE150/CIE3In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the use of…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 150- 955/A/BAQE/5.5 T MCE55/CIE3 - 60191993

    DAB CM-GE 150- 955/A/BAQE/5.5 T MCE55/CIE3In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the use…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 150-1322/A/BAQE/7.5 T MCE110/CIE3 - 60167290

    DAB CM-GE 150-1322/A/BAQE/7.5 T MCE110/CIE3In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the use of…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 150-1600/A/BAQE/11 T MCE110/CIE3 - 60167291

    DAB CM-GE 150-1600/A/BAQE/11 T MCE110/CIE3In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the use of…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 150-1950/A/BAQE/15 T MCE150/CIE3 - 60167292

    DAB CM-GE 150-1950/A/BAQE/15 T MCE150/CIE3In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the use of…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 65- 920/A/BAQE/0.75 T MCE30/C IE3 SPECIAL VERSION - 60191994

    DAB CM-GE 65- 920/A/BAQE/0.75 T MCE30/C IE3 SPECIAL VERSIONIn-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 65-1200/A/BAQE/1.5 T MCE30/C IE3 SPECIAL VERSION - 60191995

    DAB CM-GE 65-1200/A/BAQE/1.5 T MCE30/C IE3 SPECIAL VERSIONIn-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 80- 650/A/BAQE/0.75 T MCE30/C IE3 SPECIAL VERSION - 60191996

    DAB CM-GE 80- 650/A/BAQE/0.75 T MCE30/C IE3 SPECIAL VERSIONIn-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CM-GE 80- 890/A/BAQE/1.5 T MCE30/C IE3 SPECIAL VERSION - 60191997

    DAB CM-GE 80- 890/A/BAQE/1.5 T MCE30/C IE3 SPECIAL VERSIONIn-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CME 40-1450 T MCE30/C SPECIAL VERSION - 60147374

    DAB CME 40-1450 T MCE30/C SPECIAL VERSIONIn-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the…

    View Product
    Logo for DAB
    DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged
    DAB CME 50-1420 T MCE30/C SPECIAL VERSION - 60147375

    DAB CME 50-1420 T MCE30/C SPECIAL VERSIONIn-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the…

    View Product

Frequently Asked Questions

Quick answers to common questions about the DAB Single Electronic Pumps – 4 pole – CME / CM-GE – Flanged. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.

What is a water booster pump?

A water booster pump increases the pressure of an existing water supply to give stronger flow at taps, showers and appliances. It can be a small inline pump fitted to the incoming mains, or a larger pump and tank set that draws from a break tank to feed the whole house. Boosters do not create water – they raise the pressure of the water already coming in.

What is the difference between an inline booster and a tank-and-pump booster?

An inline booster connects straight onto the incoming mains and is limited to 12 litres per minute under UK water regulations – examples include the Salamander HomeBoost and WaterBoost WB-Compact. A tank-and-pump booster, such as the Grundfos Home Booster or DAB Esybox with Esytank, draws from a break tank and can deliver much higher flow rates for larger homes with multiple bathrooms.

What is a variable speed booster pump?

A variable speed booster uses an inverter to adjust pump speed in real time to match demand. It maintains constant pressure as outlets open and close, runs more quietly than a fixed-speed pump and typically saves up to 50 per cent of the energy a fixed-speed equivalent would use. The DAB Esybox, DAB Esybox Mini 3 and Grundfos Scala2 are common variable speed examples.

What does a water booster pump do?

A water booster pump raises water pressure to help supply taps, showers and other outlets when the existing system cannot meet demand.

Can a booster pump connect directly to the water mains?

Not every booster can. Direct connection depends on the product design and applicable water regulations; some systems require a break tank.

How do I size a water booster pump?

Assess simultaneous flow demand, required outlet pressure, available inlet conditions and the pressure losses in the pipework.