Pedrollo VX-MF Micro-Cast Stainless Steel Vortex Sewage Pumps
The Pedrollo VX-MF is a submersible vortex pump with a micro-cast AISI 316L stainless steel body, for demanding sewage and waste water duties in domestic, civil and industrial settings. Eight sizes deliver up to 750 l/min and up to 15 m head, with motors from 0.55 to 1.5 kW, each in single-phase VXm (230 V) and three-phase VX (400 V).
Micro-cast AISI 316L pump body, AISI 316L shaft, AISI 304 VORTEX impeller, base and motor sleeve, and a double mechanical seal in an oil chamber. The VORTEX impeller passes solids up to Ø 40 mm (/35) or Ø 50 mm (/50) without clogging. Single-phase models have a float switch and Schuko plug; all have a 10 m cable.
| Model | Code | Supply | Power | Flow | Head |
|---|---|---|---|---|---|
| VXm 8/35-MF | 2300670 | Single Phase | 0.55 kW / 0.75 HP | 50–350 l/min | 8–1 m |
| VXm 10/35-MF | 2300680 | Single Phase | 0.75 kW / 1 HP | 50–400 l/min | 10–2 m |
| VXm 15/35-MF | 2300690 | Single Phase | 1.1 kW / 1.5 HP | 50–500 l/min | 13.5–2 m |
| VXm 20/35-MF | 2300700 | Single Phase | 1.5 kW / 2 HP | 50–600 l/min | 15–1.5 m |
| VXm 8/50-MF | 2300710 | Single Phase | 0.55 kW / 0.75 HP | 50–450 l/min | 6–1.5 m |
| VXm 10/50-MF | 2300720 | Single Phase | 0.75 kW / 1 HP | 50–550 l/min | 8.5–1.5 m |
| VXm 15/50-MF | 2300730 | Single Phase | 1.1 kW / 1.5 HP | 50–650 l/min | 11–2 m |
| VXm 20/50-MF | 2300740 | Single Phase | 1.5 kW / 2 HP | 50–750 l/min | 13–2.5 m |
| VX 8/35-MF | 2300750 | Three Phase | 0.55 kW / 0.75 HP | 50–350 l/min | 8–1 m |
| VX 10/35-MF | 2300760 | Three Phase | 0.75 kW / 1 HP | 50–400 l/min | 10–2 m |
| VX 15/35-MF | 2300770 | Three Phase | 1.1 kW / 1.5 HP | 50–500 l/min | 13.5–2 m |
| VX 20/35-MF | 2300780 | Three Phase | 1.5 kW / 2 HP | 50–600 l/min | 15–1.5 m |
| VX 8/50-MF | 2300790 | Three Phase | 0.55 kW / 0.75 HP | 50–450 l/min | 6–1.5 m |
| VX 10/50-MF | 2300800 | Three Phase | 0.75 kW / 1 HP | 50–550 l/min | 8.5–1.5 m |
| VX 15/50-MF | 2300810 | Three Phase | 1.1 kW / 1.5 HP | 50–650 l/min | 11–2 m |
| VX 20/50-MF | 2300820 | Three Phase | 1.5 kW / 2 HP | 50–750 l/min | 13–2.5 m |
Head shown as the working range from minimum to maximum flow. Performance to Pedrollo 50 Hz data.
16 products
The Pedrollo VXm 8/35-MF is a 0.55 kW (0.75 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VXm 10/35-MF is a 0.75 kW (1 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VXm 15/35-MF is a 1.1 kW (1.5 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VXm 20/35-MF is a 1.5 kW (2 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VXm 8/50-MF is a 0.55 kW (0.75 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VXm 10/50-MF is a 0.75 kW (1 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VXm 15/50-MF is a 1.1 kW (1.5 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VXm 20/50-MF is a 1.5 kW (2 HP) micro-cast stainless steel submersible vortex pump for sewage on a 230 V single-phase supply, delivering…
The Pedrollo VX 8/35-MF is a 0.55 kW (0.75 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
The Pedrollo VX 10/35-MF is a 0.75 kW (1 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
The Pedrollo VX 15/35-MF is a 1.1 kW (1.5 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
The Pedrollo VX 20/35-MF is a 1.5 kW (2 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
The Pedrollo VX 8/50-MF is a 0.55 kW (0.75 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
The Pedrollo VX 10/50-MF is a 0.75 kW (1 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
The Pedrollo VX 15/50-MF is a 1.1 kW (1.5 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
The Pedrollo VX 20/50-MF is a 1.5 kW (2 HP) micro-cast stainless steel submersible vortex pump for sewage on a 400 V three-phase supply, delivering…
Frequently Asked Questions
Quick answers to common questions about the Pedrollo VX-MF Micro-Cast Stainless Steel Vortex Sewage Pumps. For technical specifications, see the product details above; for sizing or installation advice, contact our team. If you have any other questions, we're happy to help.
What is a submersible pump?
A submersible pump is designed to operate fully submerged in the liquid it is moving. The motor is sealed inside the pump body and cooled by the surrounding water. Submersibles are used for drainage, sewage, septic tanks, deep wells and boreholes, and for raising water from sumps, cellars and floodwater. Many stocked at Anglian Pumping handle solids in suspension.
Can submersible pumps handle solids and sewage?
Yes – some submersibles are designed for clean water only, others handle solids up to 50 mm or full raw sewage. Anglian Pumping stocks ABS, BBC, Flygt and T-T Submersibles ranges that include vortex, single channel and grinder impellers for different solids handling requirements. Always match the pump to the maximum solid size and the type of effluent it will see.
When should I use a submersible pump instead of a surface pump?
Use a submersible when the water level is more than around 8 metres below the pump installation point – surface pumps cannot self-prime beyond that depth. Submersibles are also better when the liquid contains solids, when noise must be minimised, or when the pump needs to operate in confined spaces such as sumps and chambers where a surface pump would not fit.